The formula
is the starting concentration, the dilution factor at each step and the number of steps. Each transfer moves of sample into of diluent, where is the final volume of each tube.
Where it comes from
A single dilution follows : the amount of solute doesn’t change, it’s just spread through more liquid. A 1:10 dilution, one part sample in ten parts total, cuts the concentration by 10.
A serial dilution repeats that step, each time starting from the tube before. Each step divides by again, so after steps the concentration has been divided by multiplied by itself times, .
Why not do it in one go? Getting a 1:1,000,000 dilution in one step would mean pipetting 1 µL into a litre. Six 1:10 steps use easy, accurate volumes instead.
Worked example
A bacterial culture at cells/mL, diluted 1:10 six times into 1 mL tubes:
Each tube gets 900 µL of diluent, then 100 µL from the tube before. Plating 100 µL from the last tube should give about 10 colonies.
Watch out for
- Errors compound. A small pipetting error repeats at every step. Mix each tube well and change tips between transfers.
- Dilution factor vs ratio. “1:10” in biology usually means 1 part in 10 total (factor 10). Some fields write 1:9 for the same thing (1 part to 9 parts diluent). Check which one a protocol means.